Items

Unit

Parameter

Type


Alkaline electrolyzer

Hydrogen capacity

Nm3 /h

400-1000

Oxygen capacity

Nm3 /h

200-500

Hydrogen purity

%(v/v)

99.9

Oxygen purity

%(v/v)

99.5

Moisture content

g/Nm3 H2

4

Turn down range


40-100%

Max. operation pressure

MPa

3.0

Pressure difference

mmH2O

≤±50

Working current

A

9000

Operating temperature

~90

DC power consumption

kw·h/m3 H2

4.4

Control mode

PLC

PLC

electrolyte


30   %KOH

Diaphragm material


Asbestos/non asbestos

Ambient temperature

5-50

Installation


Skid mounted


Maximum operating pressure to 3.0 MPa.

Automatic control, unattended operation.

Remote monitoring through the Internet.